Indonesia Healthcare Corporation IHC ICT Cybersecurity emblem
Theme
Language
0-Day / ZDI High · CVSS 7.8

ZDI-26-1105: (Pwn2Own) NVIDIA Megatron Bridge ModelConfig Unsafe Reflection Remote Code Execution Vulnerability

24 November 2026 ·CVE-2026-61754

Summary

This security advisory details a Remote Code Execution (RCE) vulnerability tracked as CVE-2026-61754 (Advisory ID: ZDI-26-1105) in NVIDIA Megatron Bridge. The flaw stems from unsafe reflection during model metadata handling when importing modules based on user-supplied arguments. Exploitation requires user interaction, requiring the target to open a malicious file or visit a crafted webpage. Successful exploitation allows an attacker to execute arbitrary code within the application container.

Affected Products

  • NVIDIA Megatron Bridge

Technical Details

The flaw exists within the handling of model metadata in NVIDIA Megatron Bridge. The application process fails to properly restrict a user-supplied argument before utilizing it to dynamically import a module (unsafe reflection). An attacker can leverage this vulnerability to trigger execution of arbitrary code within the context of the application container.

  • CVE ID: CVE-2026-61754
  • CVSS Score: 7.8 (High)
  • CVSS Vector: AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
  • Credit: Yoseop Kim (@pwning_me) via Pwn2Own

Impact

Successful exploitation allows remote attackers to execute arbitrary code inside the NVIDIA Megatron Bridge application container.

  • Confidentiality: High — An attacker can gain unauthorized access to sensitive application data and model metadata stored within the container.
  • Integrity: High — An attacker can modify application files, data, or system configurations inside the container.
  • Availability: High — An attacker can cause service disruption or crash the application container.

Mitigation & Remediation Recommendations

  • Apply the official security patch/update released by NVIDIA.
  • Refrain from opening untrusted model configuration files or visiting unverified links.
  • Enforce the principle of least privilege for container environments to limit the blast radius if compromised.

References

Advisory ini disajikan tim ICT Cybersecurity PT Pertamina Bina Medika IHC sebagai informasi kesadaran keamanan. Verifikasi pada sumber resmi sebelum tindakan.

Advisory Lain