Summary

This advisory covers a Local Privilege Escalation vulnerability in ChargePoint Home Flex EV chargers, tracked as CVE-2026-131814 and ZDI-26-1110. Discovered during the Pwn2Own competition by researchers from Team DDOS, the vulnerability stems from a command injection flaw within the tar function inside the dwnldlogsm component. A local attacker with low privileges can exploit this issue to escalate privileges and execute arbitrary code with root context.

Affected Products

  • ChargePoint Home Flex (firmware versions prior to 2024.02.00.259-alpha)

Technical Details

The vulnerability (CVE-2026-131814) exists within the tar function in the dwnldlogsm utility of ChargePoint Home Flex EV chargers. The issue results from improper validation of user-supplied strings before passing them to a system call execution.

To exploit this vulnerability, an attacker must first obtain the ability to execute low-privileged code on the target system. By leveraging the unsanitized input passed to the tar function call, the attacker can perform command injection to escalate local privileges to root.

  • CVSS v3.1 Score: 7.8 (High) — AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Impact

Successful exploitation allows a local low-privileged attacker to obtain full control of the ChargePoint Home Flex EV charger by executing arbitrary code as root.

  • Confidentiality: High — An attacker with root privileges can read all sensitive data, configuration files, and system logs on the device.
  • Integrity: High — The attacker can alter system files, modify settings, or inject arbitrary code into the device.
  • Availability: High — The attacker can disable EV charging capabilities or cause a complete denial of service (DoS) state on the device.

Mitigation & Remediation Recommendations

  • Update ChargePoint Home Flex firmware to version 2024.02.00.259-alpha or later.
  • Restrict physical and local network access to EV charging equipment to lower the risk of unauthorized local code execution.
  • Apply the principle of least privilege across operational networks and host systems.