Indonesia Healthcare Corporation IHC ICT Cybersecurity emblem
Theme
Language
0-Day / ZDI Medium · CVSS 6.8

ZDI-26-1008: (Pwn2Own) Qualcomm Technologies QCA7005 GreenPhy Heap-based Buffer Overflow Code Execution Vulnerability

13 November 2026 ·CVE-2026-25293
ZDI-26-1008: (Pwn2Own) Qualcomm Technologies QCA7005 GreenPhy Heap-based Buffer Overflow Code Execution Vulnerability

Summary

Qualcomm Technologies QCA7005 powerline communication chips contain a heap-based buffer overflow vulnerability identified as CVE-2026-25293. A physically present attacker can exploit this issue without authentication to execute arbitrary code on affected installations.

Affected Products

  • Qualcomm Technologies QCA7005

Technical Details

  • CVE ID: CVE-2026-25293
  • CVSS Score: 6.8 (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H)
  • Vulnerability Type: Heap-based Buffer Overflow

The specific flaw exists within the handling of vendor-specific GreenPhy management messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code on the powerline communication chip.

Impact

  • Arbitrary code execution on the powerline communication chip.
  • High impact on confidentiality, integrity, and availability of the affected chip.

Mitigation

  • Apply the software update issued by Qualcomm Technologies to address this vulnerability.
  • Restrict physical access to vulnerable equipment to prevent unauthorized physical manipulation.

References

Advisory ini disajikan tim ICT Cybersecurity PT Pertamina Bina Medika IHC sebagai informasi kesadaran keamanan. Verifikasi pada sumber resmi sebelum tindakan.

Advisory Lain